Common issues across the simulation engines (Quick, Rigorous) and agent-driven Optimize, plus how to resolve them.

"Backend unavailable"

Cause: The Railway container hosting the Rigorous (DWSIM) backend or the IDAES optimization backend is sleeping or restarting (cold start).

Fix:

  1. Wait approximately 30 seconds.
  2. Press Run again.
  3. If the issue persists after 60 seconds, check Railway status.
info

The container auto-wakes on the first request. Subsequent requests within the active window respond in 2 – 10 seconds.

Rigorous (DWSIM) errors

FileNotFoundException: DWSIM.Automation.dll

Cause: DWSIM_PATH environment variable is unset or points at a directory that doesn't contain the DWSIM DLL set. Only relevant when self-hosting the Rigorous backend.

Fix: Install DWSIM and set DWSIM_PATH to its install directory (e.g. /usr/local/lib/dwsim). The directory must contain DWSIM.Automation.dll and its transitive dependencies. The assembly resolver in Program.cs reads from this path on demand.

"Compound not found: <name>"

Cause: DWSIM couldn't resolve the component via CAS → name → formula fallback.

Fix: Add the CAS number to the component in Jasper (most reliable), or check that the name matches DWSIM's compound database casing.

Rigorous solve timeout (>5 min)

Cause: The Rigorous backend caps each job at 5 minutes (Program.cs).

Fix: Difficult recycles are the most common cause. Tighten tear-stream specifications, simplify the flowsheet, or split it into stages.

"Rigorous simulation requires Jasper Pro"

Cause: Rigorous mode is part of the Jasper Pro tier.

Fix: Upgrade to Pro, or stay in Quick mode for screening / ideal systems.

Optimize (IDAES, agent-driven) errors

note

Optimization is invoked through the Jasper agent — ask in chat (e.g. "minimize H1 duty by varying its outlet temperature between 305 K and 360 K"). There is no separate Optimize button. Errors below surface either in the agent's tool-call result or in the inline result card.

"Degrees of freedom != 0"

Cause: The flowsheet is under-specified (DOF > 0) or over-specified (DOF < 0). IDAES requires an exactly square system.

Fix:

  • DOF > 0 (under-specified): Add missing specifications. Common omissions:
    • Feed stream temperature, pressure, or flow rate
    • Feed composition (must be specified for all components)
    • Unit operation parameters (flash temperature, heat duty, split fraction)
  • DOF < 0 (over-specified): Remove redundant specifications. For example, specifying both outlet temperature and heat duty on a heater over-constrains the system.
Example: Flash drum with 3-component feed
Required specs: T_feed, P_feed, flow, x1, x2 (x3 = 1 - x1 - x2), T_flash, P_flash
DOF = 0 ✓

"Solver did not converge" (IPOPT)

Cause: IPOPT could not find a feasible solution within the iteration limit or tolerance.

Fix (in order of likelihood):

  1. Check initial guesses. Poor initial values for temperature and pressure cause the solver to diverge.
  2. Reduce complexity. Solve a simpler sub-flowsheet first, then add blocks incrementally.
  3. Increase iterations. Set max_iterations to 200 or 500 for large flowsheets.
  4. Try a different property package. SRK and PR generally converge more reliably than activity coefficient models.
  5. Check for impossible specifications. A heater can't cool below ambient with positive duty. A flash outside the two-phase envelope produces trivial solutions.
warning

If the solver reports "infeasible," the specifications are likely physically inconsistent. Review your feed conditions and unit parameters before increasing iterations.

"Rate limit exceeded"

Cause: More than 10 simulation submissions in the last 60 seconds from your IP (Optimize backend only).

Fix: Wait 1 minute. The rolling window resets automatically.

Validation errors (all modes)

These errors are caught before the solver runs.

Disconnected blocks

Error: Block "Heater-1" has no inlet connection

Every unit operation (except Feed blocks) must have at least one connected inlet. Check that all arcs are properly connected in the flowsheet editor.

Missing specifications

Error: Feed "Feed-1" missing required specification: pressure

All Feed blocks require temperature, pressure, total flow, and composition for every component in the system.

Compositions do not sum to 1

Error: Feed "Feed-1" mole fractions sum to 0.95, expected 1.0

Mole fractions must sum to 1.0 within floating-point tolerance.

Unknown component

Error: Component "CustomChem" not found in database

Each mode draws from its own component database. Custom or misspelled names are rejected. Check the component selector for available species.

Still stuck?

If none of the above resolves your issue:

  1. Open the browser developer console (F12 → Console) and check for network errors.
  2. Verify your flowsheet solves in Quick mode first — this validates topology independently of any backend.
  3. Simplify the flowsheet to the minimum reproducing case.